Wavin

Low noise soil & waste system
For more details contact Astral Poly Technik Limited
Exclusive distributor for Wavin AS products in India.

  AVAILABLE SIZE
• DN 70 mm, DN 100 mm, DN 150 mm, DN 200 mm

  • About Product
  • Pipe
  • Fittings
  • Installation Guide
Increased noise protection

Where a level of sound insulation greater than the minimum values specified is desirable, this must be established in contracts between the contractor and the awarding authority. The following technical regulations, which are not included in planning legislation, contain relevant advice and suggestion, which require a contractual agreement to become binding.

DIN 4109 Supplement 2:

This contain instructions relating to noise levels that lie 5 dB (A) below the values given in DIN 4109/A1: 2001-01 Table 4, In accordance with Supplement 2, increased levels of sound insulation can be arranged, by agreement, to a maximum of 25 dB (A) in other areas requiring noise protection.

VDI 4100

In contract to the requirements of DIN 4109, which was adopted as noise protection level I (NPL I), this guideline contains characteristic values for two additional noise protection level - NPL II and NPL III. These two additional noise protection levels specify the arrangements for increased sound insulation

The design of residential buildings with high noise protection requirements requires the coordination of all participating contractors. The consultation of an acoustic engineer is recommended.

Noise control measures
Sources of noise in building equipment and appliances

The noise generated by plant and equipment providing services to buildings may be classified as follows:

Noise due to filling operations

Noise generated by control equipment

Intake noise

Discharge noise

Noise due to impact or shock

Noise is generated by moving parts or by flowing media. Waste water discharge pipes are prone to vibration, particularly where water flows through downpipes, or is forced to change direction in joints and elbows (noise due to impact or shock). Experience shows that the greatest problems are typically caused by the transmission of structural noise, particularly in the area of pipe clamps and brackets or where pipe-work is run through walls or ceilings.

Building layout

An important step towards fulfilling noise protection requirements at the agreed levels is the design and production of an acoustically appropriate building layout. The following are a few - but not all - of the measures, which should be taken:

Noise-sensitive areas should be kept as far as possible from sources of noise

Non-sensitive areas should, wherever possible, be used as "buffer zones"

Non-sensitive areas should not be positioned in the direct vicinity of bathrooms, toilets or stairwells.

Potential sources of noise should be "bundled together" in the same area

The comparison of the floor plans above demonstrates how good acoustic design in the lower building example can significantly reduce the noise levels to which areas requiring noise protection are exposed.

Planning pipe installation

The installation of Wavin waste systems can significantly reduce noise levels when compared with other piping systems. When installing high-performance sound-insulating waste water piping systems such as Wavin, however, it is still necessary to consider how effectively the system can be sound-isolated. This applies to the waste water discharge system as a whole, including its points of contact with the building structure (pipe brackets and clamps, the running of pipework through walls and ceilings, mortar droppings between pipes and wall surfaces, etc.). When planning pipe installation, waste water discharge pipes should not be allowed to run inside the walls separating living areas. The attachment of waste water discharge pipes to partition walls in living areas should only be carried out under application of special noise protection measures. DIN 4109 requires that single-skin walls to which, or in which, water installations or equipment (i.e. waste water pipes) are to be attached must have an area-related mass of at least 220 kg/sq.m. Walls having an area-related mass of less than 220 kg/sq.m may only be used where prior testing has demonstrated that the walls exhibit acceptable properties with respect to the transmission of noise.


Waste water engineering to DIN 12056 and DIN 1986-100
Installation and rating of waste water removal systems


The following principles must be observed with respect to waste water removal systems:

The system design should ensure that there are no significant pressure fluctuations which could cause the level of the trap water seal to be compromised.

Reliable ventilation must be provided for the waste water removal system.

A self-cleaning effect must be achieved.

Nominal diameters should be kept to a minimum.

Waste water must discharge at low noise levels.

Waste water removal systems

At European level, 4 different waste water removal systems have been established, which comply with DIN EN 12056-2, Section 4.2.

System I

Single downpipe with part-filled connecting pipe and a filling factor of 0.5 (mainly used in Germany where this is the only approved waste water system)


System II

Single downpipe with part-filled connecting pipe, reduced damensions and a filling factor of 0.7 (mainly used in Scandinavia)

System III

Single downpipe with fully-filled connecting pipe and a filling factor of 1.0 (mainly used in English-speaking countries)

System IV

Consists of two separate pipe systems - sewage and grey-water - (mainly used in France)

Classification of nominal diameters

In accordance with DIN EN 12056, the nominal diameter (DN) is a suitable round number, more or less equal to the (external) diameter. Each nominal diameter (DN) is allocated a minimum internal diameter, dimin (see Table 2). For the purposes of calculation, the minimum internal diameter or actual internal diameter specified by the pipe manufacturer is normally used.

Problem: Product standards for pipes and fittings are generally specified using the external diameter parameter, even though the outer diameters do not always correspond to the values given in DIN EN 12056 (see DN 100 => DA 110).

Pipe Range

    Dim.   
DN
Article
No.
d
mm
s
mm
L
mm
Weight
kg/m
Standard
Packing
56 91.1.0000 58 4,0 3000 1,40 30
70 91.1.0002 78 4,5 3000 2,10 38
90 91.1.0005 90 4,5 3000 2,30 35
100 91.1.0004 110 5,3 3000 3,55 29
125 91.1.0006 135 5,3 3000 4,40 23
150 91.1.0008 160 5,3 3000 5,15 20
200 91.1.0010 200 6,3 3000 7,50 14

    Dim.   
DN
Article
No.
L
mm
Weight
kg/pc.
Standard
Packing
56 91.1.0100 150 0,30 672
70 91.1.0102 150 0,45 360
90 91.1.0103 150 0,55 240
100 91.1.0104 150 0,78 196
125 91.1.0106 150 1,01 140
150 91.1.0108 150 1,20 100

    Dim.   
DN
d
mm
d1
mm 
s
mm
t
mm
56 58  75 4,0 54
70 78  96 4,5 56
90 90  110 4,5 55
100 110  132 5,3 61
125 135  161 5,3 64
150 160  181 5,3 66
200 200  227 6,2 85

Fitting Range
    Dim.   
DN
Article
No.
OD
mm
100/70/56 (3×)
91.1.5670 100/78/58 (3×)

    Dim.   
DN
Article
No.
d1
mm
d2
mm
t
mm
 t1
mm
t2
mm
L
mm
Weight
kg/pc.
Standard
Packing
56 91.1.2000 175 172
49
5
15
126 0,20 924
70 91.1.2002 196 184  48  6  16 119
0,30 576
90 91.1.2003 110 104
 47  6  16 123
0,30 400
100 91.1.2004 132 116
 48  6  16 124
0,49 308
125 91.1.2006 161 141
 63  6  16 132
0,66 192
150 91.1.2008 181 166
 63  6  16 144
0,75 120

    Dim.   
DN
Article
No.
L
mm
Weight
kg/pc.
Standard
Packing
200 91.1.2022 168 1,33 75

    Dim.   
DN
Article
No.
L
mm
Weight
kg/pc.
Standard
Packing
56 91.1.2010 105 0,18 1000
70 91.1.2012 107 0,26 640
100 91.1.2014 117 0,43 336
125 91.1.2016 124 0,56 216
150 91.1.2018 143 0,62 140
200 91.1.2020 168 1,30 140

    Dim.   
DN
Article
No.
d1
mm
t
mm
te
mm
L
mm
Weight
kg/pc.
Standard
Packing
100 91.1.2400 110 127 74  210 0,80 196

    Dim.   
DN
Article
No.
d1
mm
t
mm
te
mm
z1
mm
z2
mm
Weight
kg/pc.
Standard
Packing
100 91.1.2390 110 57 250
24  28 1,42 112

    Dim.
DN
Article
No.
z1
mm
z2
mm
z3
mm
 z4
mm
a
mm
Weight
kg/pc.
Standard
Packing
100 91.1.2290 78 58 44 28
19,5
1,24 110

    Dim.   
DN
Article
No.
L
mm
Weight
kg/pc.
Standard
Packing
156 91.1.2340 49 0,11 1000
170 91.1.2342 52 0,20 100
190 91.1.2343 40 0,18 800
100 91.1.2344 57 0,37 500
125 91.1.2346 60 0,51 200
150 91.1.2348 49 0,54 300

    Dim.   
DN
º  Article
No.
z1
mm
z2
mm
Weight
kg/pc.
Standard
Packing
56 15º
91.1.2200 19 8
0,22 960
56
30º
91.1.2220 24 16
0,21
800
56
45º 91.1.2240 28
17
0,22
800
56 67º  91.1.2260 43
21
0,23
660
56 87º  91.1.2270 47 32
0,25
768
70 15º 91.1.2202 26 10
0,33
500
70 30º 91.1.2222 30 17
0,37
480
70 45º 91.1.2242 37 21 0,39 480
70 67º 91.1.2262 48 31 0,42 400
70 87º 91.1.2272 62 42 0,46 340
90 15º 91.1.2203 8 8 0,33 380
90 30º 91.1.2223 15 14 0,35 340
90 45º 91.1.2243 22 20 0,36 320
90 87º 91.1.2273 49 42 0,41 256
100 15º 91.1.2204 27 15 0,61 220
100 30º 91.1.2224 37 19 0,65 224
100 45º 91.1.2244 44 28 0,71 196
100 67º 91.1.2264 60 44 0,74 168
100 87º 91.1.2274
78 58 0,89 144
125 15º 91.1.2206 29 16 0,81 160
125 30º 91.1.2226 38 45 0,91 120
125 45º 91.1.2246 50 34 0,98 120
125 87º 91.1.2276 96 102 0,17 80
150 15º 91.1.2208 13 19 0,89 100
150 30º 91.1.2228 24 30 1,00 100
150 45º 91.1.2248 36 42 1, 28 64
150 87º 91.1.2278 83 89 1,62 48
200 45º 91.1.2250 47 42 1,99 40
200 87º 91.1.2280 103 93 2,51 32

    Dim.   
DN
Article
No.
d1
mm
d2
mm
z1
mm
z2
mm
Weight
kg/pc.
Standard
Packing
56/40 91.1.2380 50
58
30,5 25
0,08 800

    Dim.   
DN
º  Article
No.
z1
mm
z2
mm
z3
mm
Weight
kg/pc.
Standard
Packing
56/56 45º
91.1.2030 28
74
74 0,43
424
56/56
67º
91.1.2060 36
45
45 0,38
400
56/56
87º 91.1.2080 48
32
32 0,37
336
70/56 45º  91.1.2032 17
83
79 0,58
280
70/56 67º  91.1.2062 31
54
46 0,51
280
70/56 87º 91.1.2082 48
42
28 0,49
320
70/70 45º 91.1.2034 38
99
99 0,75
216
 70/70 67º 91.1.2064 47
61
60 0,64
252
 70/70 87º 91.1.2084 62
43
43 0,59
240
90/56
45º
91.1.2037 -3
97
84 0,70
224
90/56
87º
91.1.2041 32
48
31 0,58
224
90/70
87º
91.1.2043 43
49
40 0,69
186
90/90
45º
91.1.2035 19
113
106 0,70
168
90/90
87º
91.1.2039 72
72
37 0,79
168
100/56
45º
91.1.2036 1
110
97 0,94
140
100/56
67º
91.1.2066 24
75
52 0,82
140
100/56
87º
91.1.2086 47
61
27 0,78
160
100/70
45º
91.1.2038 21
122
115 1,22
112
100/70
67º
91.1.2068
40
81
67 1,00
120
100/70
87º
91.1.2105 72
90
47 1,00
140
100/70
87º
91.1.2088 60
61
43 0,94
140
100/100
45º
91.1.2040 44
136
136 1,50
88
100/100
67º
91.1.2070 58
84
84 1,32
96
100/100
87º
91.1.2090 78
58
58 1,10
112
100/100
87º
91.1.2103 100
88
47 1,23
112
125/100
45º
91.1.2042 31
155
152 1,90
62
125/100
87º
91.1.2092 78
73
59 1,59
72
125/125
45º
91.1.2044 49
169
169 2,04
56
125/125
87º
91.1.2094 90
72
72 1,56
60
 150/100 45º 91.1.2046  2 168 159 2,14 46
150/150  45º 91.1.2048  36 194 194 2,85 24
 200/200 87º 91.1.2050  42 247 239 4,40 16

    Dim.   
DN
Article
No.
z1
mm
z2
mm
 z3
mm
Weight
kg/pc.
Standard
Packing
90/9090 91.1.2122 79 72  60 1,06 80
100/100/100 91.1.2110
78 58  58 1,58 80

    Dim.   
DN
Article
No.
z1
mm
z2
mm
 z3
mm
 z4
mm
 z5
mm
 a
mm
b
mm
L
mm
Weight
kg/pc.
Standard
Packing
100/100 91.1.2120
44 136  136  44 28
 129 19,5
320
1,93
70

    Dim.   
DN
Article
No.
z1
mm
z2
mm
 z3
mm
 z4
mm
Weight
kg/pc.
Standard
Packing
100/100/70 91.1.2108
80 80  58  104 1,92
80

    Dim.   
DN
Article
No.
L
mm
Weight
kg/pc.
Standard
Packing
56 91.1.2320
 151 0,30
480
 70 91.1.2322  187  0,91 196
 90 91.1.2331  148  1,93  80

    Dim.   
DN
Article
No.
L
mm
Weight
kg/pc.
Standard
Packing
100 91.1.2330
298 2,17
72
125 91.1.2332 316 3,26 60
150 91.1.2334 345 3,60 40

    Dim.   
DN
Article
No.
Standard
Packing
56 91.1.2491
1
70 91.1.2493 1
100 91.1.2496 1
125 91.1.2497
1
150 91.1.2498 1

    Dim.   
DN
Article
No.
 
h
 
D

di
40 91.1.2108
30 56 40
50
91.1.2108  30 70 50
63 91.1.2108 30 75 63
75 91.1.2108 30 99 75
90 91.1.2108 30 117 90
110 91.1.2108 30 141 110
125 91.1.2108 50 154 125
140 91.1.2108 50 178 140
160 91.1.2108 50 200 160
180 91.1.2108 50 228 180
200 91.1.2108 50 253 200

    Dim.   
DN
Collar
Art.-No.
Standard
Packing
 Sealing rings
Art.-No.
Standard
Packing 
56 (58 mm)
91.1.2462
10
91.1.2442 20  
70 (75 mm)
91.1.2463 10  91.1.2443 20  
70 (78 mm)
91.1.2464 10  91.1.2444 20  
90
91.1.2465
 10  91.1.2445 20  
 100  91.1.2466  10  91.1.2446 20  
 125  91.1.2467  10  91.1.2447 20  
 150  91.1.2468 10
 91.1.2448 20  
 200  -  -  91.1.2450 20  

    Dim.   
DN
Article
No.
56 11.5.1800
70
11.5.1802
90 11.5.1804
100 11.5.1806
125 11.5.1808
150 11.5.1810
200 11.5.1812


    Dim.   
DN
Article
No.
Standard
Packing
56 91.1.2420
1320
70 91.1.2421 960
90 91.1.2425 720
100
91.1.2422
 540
 125  91.1.2423  360
 150  91.1.2424  240

 Description Article
No
    Dim.   
DN
 Wavin PVC-U
Transition Fitting
91.1.2620 125

Guideline

  • Installation Guide

Installation Guide

Installation for Wavin
Straight ceiling installation

• Straight installation without sleeve / socket

• Straight installation with sleeve / socket

Wrap insulating mat around the pipe. Open the collar and position it around the pipe, whilst hooking in the push-in fastening. Fill the remaining gap with cement or concrete (see general recommendations (4)). Hold the collar firmly against the ceiling and mark the positions of the mounting holes.

Rotate the collar and drill the holes.

Insert plugs and fix the collar using screws and washers. (Mounting the collar using the washers, plugs and screws provided).

Flush ceiling installation

Wrap insulating mat around the pipe.

Open the collar and position it around the pipe, whilst hooking in the push-in fastening. Bend or angle the collar mounting tabs. Then install the collar flush with the ceiling. Fill the remaining ceiling gap with cement or concrete (see general recommendations (4)).

Angled ceiling installation

Wrap insulating mat around the pipe.

Open the collar and position it around the pipe, whist hooking in the push-in fastening. Fill the remaining gap with cement or concrete (see general recommendations (4).

Hold the collar firmly against the ceiling and mark the positions of the mounting holes.

Rotate the collar and drill the holes.

Insert plugs and fix the collar using screws and washers. (Mounting the collar using the washers, plugs and screws provided).

Wall installation

• in solid walls with sleeve

• in solid walls without sleeve

• in plasterboard walls with sleeve*

• in plasterboard walls without sleeve*

• Angled installation up to 45º

*Note: fittings for installation in plasterboard walls are not included.

Wrap insulating mat around the pipe. Open the collar and position it around the pipe, whilst hooking in the push-in fastening. Fill the remaining gap with cement or concrete (see general recommendations (4). Hold the collar firmly against the ceiling and mark the positions of the mounting holes.

Rotate the collar and drill holes.

Insert plugs and fix the collar using screws and washers. (Mounting the collar using the washers, plugs and screws provided).

Repeat the steps described for the second collar required on the opposite side.